Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Indian J Ophthalmol ; 2010 May; 58(3): 248-252
Article in English | IMSEAR | ID: sea-136068

ABSTRACT

The sulphonamide group of drugs is implicated in bilateral acute angle closure (AAC) due to an idiosyncratic response. We report a series of three cases with bilateral AAC caused by different sulphonamide derivatives, their presentation and management.


Subject(s)
Acute Disease , Adult , Female , Glaucoma, Angle-Closure/chemically induced , Humans , Hypoglycemic Agents/adverse effects , Male , Middle Aged , Sulfonamides/adverse effects
2.
Indian J Ophthalmol ; 2009 Sept; 57(5): 361-364
Article in English | IMSEAR | ID: sea-135978

ABSTRACT

Background: Assessment of optic disc size is an important component of optic nerve head examination. Agreement between different methods of disc size measurements is not very good. Purpose: To assess the agreement between the disc size assessed by Heidelberg retina tomograph (HRT) and stereobiomicroscopy with a 90 diopter (D) lens. To report the clinical (measured by biomicroscopy) disc diameters of small, average and large optic discs categorized by HRT disc areas. Setting and Design: Observational study of subjects examined in the glaucoma clinic of a tertiary eye institute. Materials and Methods: Seventy-five eyes of 75 glaucoma subjects were studied. Disc diameter was measured using stereobiomicroscopy and HRT. The agreement between the two sets of measurements was assessed by intraclass correlation coefficient (ICC). Discs were classified into small (<1.6 mm2), average (1.6-2.6 mm2) and large (>2.6 mm2) depending on cutoffs provided by the manufacturers of HRT. The means (95% CI) of the corresponding vertical disc diameter in these groups were assessed. Statistical Analysis: ICC, Bland and Altman plots. Results: ICC for measurements of clinical and HRT horizontal disc diameter was 0.518 and for vertical disc diameter measurement was 0.487. The mean difference between the clinical and HRT measurements as analyzed by the Bland and Altman plot was 0.17 (95% CI, 0.13- 0.47) for horizontal and 0.22 (95% CI, 0.11- 0.54) for vertical disc diameter. Of the 75 eyes, 3 eyes had small discs, 54 average and 18 large discs. The mean clinical vertical disc diameter for small discs was 1.55 mm (95% CI, 1.2-1.7), for average discs was 1.91 mm (95% CI, 1.87-1.96) and for large discs was 2.15 mm (95% CI, 2.03–2.27). Conclusion: The agreement between clinical and HRT disc diameter measurements is moderate. Disc diameter measurement on stereobiomicroscopy can be used to categorize discs into small, average and large discs.


Subject(s)
Diagnostic Techniques, Ophthalmological , Female , Glaucoma/complications , Glaucoma/diagnosis , Humans , Male , Middle Aged , Observer Variation , Optic Disk/pathology , Optic Nerve Diseases/diagnosis , Optic Nerve Diseases/etiology , Reproducibility of Results , Retrospective Studies , Severity of Illness Index , Tomography/methods
SELECTION OF CITATIONS
SEARCH DETAIL